Continuous Temperature Verification
Enthermics fluid warmers that are equipped with the optional WarmWatch package feature a continuous temperature monitoring system that provides users instant visual confirmation of the chamber temperature.

In addition to the standard control probe, an independent monitoring probe located very close to the control probe verifies
that the chamber reaches and maintains the set-point temperature with +0/-1.1°C (+0/-2°F) accuracy from 37-40°C (98-104°F) and +0/-1.7°C (+0/-3°F) accuracy above 40-66°C (104-150°F). Two independent LED displays on the control panel show the set-point and actual interior temperature at a glance. (The chambers are designed not to exceed the set-point temperature, thus the nominal actual temperature will always be one to one-and-a-half degrees lower than the set-point temperature.)
Digital Documentation
In addition to continuous temperature monitoring, the WarmWatch option provides digital documentation of the warmer's historical temperature performance data. This offers significant advantages over manually recording temperature set-points or control probe displays since these values are not independently obtained, and do not verify the actual chamber temperature. The independent monitoring probe in this option ensures that the actual chamber temperature is recorded. Automatic collection also ensures consistent data samples.
The report:
- Stores up to six months of data and displays a warning when the unit approaches its memory limit
- Downloading begins automatically when a USB flash drive is connected to unit
- Accuracy report includes:
- Warmer model number, serial number, and date of manufacture
- Date of report/download
- Frequency of readings used in evaluation
- Dates included in evaluation
- Number of days included in report
- Number of readings evaluated for accuracy calculation
- Number of readings excluded from accuracy calculation due to a door opening within two hours of reading
- Mode of fluid warming (injection or irrigation)
- Set-point temperature
- Average temperature
- Temperature range during evaluation time period
- Accuracy evaluation indicating whether unit successfully maintained accuracy parameters while set to selected set point
- Raw temperature data is reported in a comma-delimited (CSV) file
For more information or specific questions about the WarmWatch option, contact Enthermics Medical Systems at: 1-800-TO-B-WARM (US and Canada) or 262-251-8356. Or contact us.